Jurnal Standardisasi

Notifications

Editorial Board

Reviewer

Journal Help

Font Size



Home Search Mail RSS


BATAN PERSONAL DOSE EQUIVALENT Hp (10) AND Hp (3) INTERCOMPARISON RESULTS AT 2018 & 2019

Assef Firnando Firmansyah, Okky Agassy Firmansyah, Rizka Sarah Melinda

Abstract


One of the methods to ensure the quality of a laboratory is participating in an intercomparison activity. For the dosimetry laboratory network in Indonesia, the intercomparison activity is managed by the Secondary Standard Dosimetry Laboratory (SSDL) Jakarta. This paper describes the intercomparison among processing laboratory for personal dose equivalent Hp(10) and Hp(3) using thermoluminescent dosimeter (TLD)/films in 2018 & 2019. The SSDL Jakarta irradiated packages of participant's TLDs/films with Cs-137 and X-rays at a specific equivalent dose. The irradiated dosimeters were sent back to the participants by mail, and then the result was sent to the SSDL Jakarta for evaluation. The evaluation was carried out using the trumpet curve under the International Atomic Energy Agency (IAEA) publication. The results obtained for the 2018 intercomparison show the success rates of 98%, and 2% were outside the acceptable range, whereas for the 2019 Intercomparison, the success rates were 96% and 4% outside the acceptable range. The potential failure of reading the dose value was in the film dosimeter/badge. For those recent two years of intercomparison activities, the success rate was more than 95%. This result of the intercomparison activity showed the excellent quality of the personal dose equivalent Hp(10) and Hp(3) measurement in Indonesia.


Keywords


intercomparison, personal dose equivalent, Hp(10), Hp(3), TLD/Film dosemeter

Full Text:

PDF

References


Adjei, D. N., Amoatey, E. A., Schandorf, C., Amoako, J. K., Manteaw, P. O., & Ondo Meye, P. (2017). Intercomparison on the Measurement of the Quantity Personal Dose Equivalent Hp(10) in Photon Fields. Linearity Dependence, Lower Limit of Detection and Uncertainty in Measurement of Dosimetry Systems of Individual Monitoring Services in Gabon and Ghana. Radiation Protection Dosimetry, 177(3), 250–260. https://doi.org/10.1093/rpd/ncx038

Arib, M., Herrati, A., Dari, F., Ma, J., & Lounis-Mokrani, Z. (2015). Intercomparison 2013 on measurements of the personal dose equivalent Hp (10) in photon fields in the African region. Radiation Protection Dosimetry, 163(3), 276–283. https://doi.org/10.1093/rpd/ncu202

Abaza, A. M. H. (2018). A new trend in radiation dosimeters. American Journal of Modern Physics, 7(1), 21-30.

https://doi.org/10.11648/j.ajmp.20180701.13

Butler, D. J., Kurasawa, T., Litwin, M., Mazaraki, J., & Saito, N. (2018). Comparison of personal dose equivalent Hp(10) in 137Cs radiation between the primary standards laboratories of Japan and Australia using Beo OSL personal dosemeters. Radiation Protection Dosimetry, 178(2), 235–241.

https://doi.org/10.1093/rpd/ncx091

Firmansyah, A. F. (2020). The Effect of Use of 137 Cs Calibration Factor on X-Ray Dose Measurement using Secondary Standard Hp (10) Ionization Chamber. Jurnal Standardisasi, 22(1), 45–54.

Firmansyah, A. F. (2017). Interkomparasi Dosis Ekivalen Perorangan Hp (10) dan Hp (3) menggunakan TLD/Film Tahun 2017. PPIPD-IPTN, November, 87–90.

Gregori, B. N., Papadópulos, S. B., Saraví, M., & Kunst, J. J. (2007). Argentine intercomparison program for personal dosimetry. Radiation Protection Dosimetry, 125(1–4), 98–100.

https://doi.org/10.1093/rpd/ncl534

Hasnel Sofyan. (2012). Dosimeter ThermoLuminesensi sebagai Dosimetri Personal dalam Pemantauan Dosis Radiasi Eksternal. Prosiding Pertemuan Ilmiah XXVI HFI Jateng & DIY, April, 129–134.

International Atomic Energy Agency. (2018). Safety Standards for protecting people and the environment General Safety Guide No. GSG-7 Occupational Radiation Protection Jointly sponsored by. In General Safety Guide. International Atomic Energy Agency. http://www-ns.iaea.org/standards/

Jumpeno, B. Y. E. B., Ekaranti, E., & Batan, P. (2017). Verifikasi Dosis H*( 10 ) Pada Evaluasi Dosis Radiasi Lingkungan Menggunakan Dosimeter OSL Verification of H *( 10 ) Dose on Environmental Dose Evaluation by Using OSL Dosimeter. Widyanuklida, 16(1), 22–28.

Kurasawa, T., Saito, N., Mazaraki, J., Litwin, M., & Butler, D. J. (2017). Comparison of Personal Dose Equivalent Hp (10) in CS-137 Radiation Between The Primary Standards Laboratories of Japan and Australia using BeO OSL Personal Dosemeters. Radiation Protection Dosimetry, 178(2), 235–241. https://doi.org/10.1093/rpd/ncx091

Msimang, Z., Cruz-Suárez, R., & Zeger, J. (2011). Intercomparison on measurements of the quantity personal dose equivalent Hp(10) in photon fields in the African region. Radiation Protection Dosimetry, 144(1–4), 282–286. https://doi.org/10.1093/rpd/ncq373

Saraví, M., Zaretzky, A., Lindner, C., Díaz, J., Walwyn, G., Amorim, R., de Souza, D., Gregori, B., Papadópulos, S., Meghzifene, A., Ferruz, P., & Suárez, R. C. (2007). Results of the regional intercomparison exercise for the determination of operational quantity HP(10) in Latin America. Radiation Protection Dosimetry, 125(1–4), 84–87. https://doi.org/10.1093/rpd/ncl538




DOI: http://dx.doi.org/10.31153/js.v23i2.892

Refbacks

  • There are currently no refbacks.