Hadi Sardjono

Abstract


As a national laboratory, Puslit KIM-LIPI has been realised it measurement capability for ac power in form of Power Source System which is performed in combination of an ac voltage source, an ac current source and a pahse shifter from 00 up to 3600. Concerning to the accuracy maintenance, it was observed by using an indirect measurement method. This measurement system was involved a several equipment standards such as a DMM (Digital Multimeter) and a wattmeter as the load and the voltage and the current value supply by the power source were measured with it accuracy limmitation up to 0.8%.

Keywords


measurement uncertainty, single phase power, indirect measurement method.

Full Text:

PDF

References


Fluke 2 nd edition. 1994. Calibration. Philosophy in Practice

Expression of Uncertainty, 1992. ISO/IEC-/OIML/BIPM

USA. March 2000. Digital Multimeter Opera-tion manual, Agilent 24401A, 5th Edition

Course notes CSIRO. 1995. Using the ISO “Guide to the expression on of Uncertainty in Measurement /GUM”




DOI: http://dx.doi.org/10.31153/js.v8i3.668

Refbacks

  • There are currently no refbacks.